Rhythm Interpretation第 28 / 100 题

A monitor alarms for ventricular fibrillation, but the technician finds the patient sitting up, alert, and brushing her teeth, and a regular narrow-complex rhythm is visible between the chaotic sections. What is the most likely explanation?

a.Intermittent true ventricular fibrillation
b.Third-degree AV block
c.Pacemaker malfunction
d.Muscle movement artifact

解析

An alert, talking patient cannot be in ventricular fibrillation, and the presence of underlying normal complexes marching through the chaos identifies the tracing as motion artifact. True ventricular fibrillation has no organized QRS complexes anywhere and produces immediate unresponsiveness. AV block and pacemaker failure both produce organized, measurable patterns rather than chaotic noise tied to the patient's activity.

免费刷完整 100 道题库 — 无需注册。

同考点相关题目

最近核对: · 审核流程

PrepPass 编辑团队 · 依据官方资料核对 NHA Certified EKG Technician (CET) Exam · 我们如何核对
反馈