Safety & Professionalism第 88 / 100 题
While attaching electrodes, the technician sees ventricular fibrillation appear on the screen and the patient becomes unresponsive. What is the first action?
a.Finish the 12-lead so the physician has a complete record
b.Document the time and rhythm in the chart
c.Reposition the electrodes to rule out artifact
d.Call for help and activate the facility's emergency response, then begin CPR according to training
解析
Ventricular fibrillation in an unresponsive patient is a cardiac arrest, and survival depends on immediate activation of the emergency response and prompt CPR and defibrillation. Completing the test or charting first wastes critical minutes. Checking for artifact is appropriate only when the patient is awake and stable, which is not the case here.
免费刷完整 100 道题库 — 无需注册。
同考点相关题目
- When must an EKG technician perform hand hygiene?
- A patient's chest has an open, draining wound near a chest electrode site. What does the bloodborne pathogens standard require of the technician?
- A patient asks the EKG technician, "Does this tracing mean I had a heart attack?" What is the appropriate response?
- During a treadmill stress test, the patient reports chest pain and the monitor shows new ST segment depression. What should the technician do?
- Which information must appear on every EKG tracing?
- What is appropriate routine maintenance for EKG equipment between patients?