Systems & Code第 46 / 110 题
A water heater is installed in a garage where flammable vapors may be present. What installation requirement addresses ignition of those vapors?
a.Install a drip leg only
b.Elevate the ignition source at least 18 in above the floor, or use an approved flammable-vapor-ignition-resistant unit
c.Provide combustion air from the attic
d.Add a second T and P valve
解析
In a garage the pilot or ignition source must be at least 18 in above the floor, because gasoline vapors are heavier than air and pool low, unless the heater is listed as flammable-vapor-ignition-resistant (FVIR). Modern FVIR heaters are designed to prevent flame rollout from igniting floor-level vapors. Combustion air and relief valves do not address vapor ignition.
法律依据: UPC §507.0免费刷完整 110 道题库 — 无需注册。
同考点相关题目
- In a medical gas piping system, oxygen and other medical gases must use tubing that is cleaned and labeled for the service. What copper tubing is required for medical gas distribution?
- Medical gas piping must be tested before use. Which test verifies the system is free of leaks and cross connections at operating conditions?
- A water softener regenerates using 8 lb of salt per cubic foot of resin for a 3 cubic foot resin bed. How much salt is consumed per regeneration cycle?
- A key difference between the Uniform Plumbing Code and the International Plumbing Code affects where the building drain becomes the building sewer. Which statement correctly pairs the codes?
- An indirect waste pipe has an effective outlet opening of 3/4 in. The required air gap above the receptor flood-level rim is two times the effective opening. What is the minimum air gap?
- A sewage ejector serving fixtures below the sewer must discharge upward and then into the gravity building drain. What fitting protects the pump from gravity backflow when it is off?