Safety第 99 / 110 题
A master plumber must braze medical gas copper, which is hot work. What fire-safety precaution is required before starting?
a.Only wear gloves
b.Work faster to reduce exposure
c.Obtain a hot-work permit, clear/cover combustibles, and post a fire watch with an extinguisher
d.Open the gas valve to purge
解析
Hot work such as brazing or soldering near combustibles requires a hot-work permit, removal or shielding of combustibles within the area, and a fire watch with an extinguisher during the work and for a period afterward. Sparks and heat can smolder in hidden materials and ignite after the crew leaves. This is standard for cutting, welding, and brazing.
法律依据: 29 CFR 1926.352免费刷完整 110 道题库 — 无需注册。
同考点相关题目
- Before entry, a manhole 4 ft in diameter and 12 ft deep must be purged with 5 air changes. Using volume = 0.785 x diameter^2 x depth (about 151 ft^3), what total air volume must be moved to complete the purge?
- A plumber sets an extension ladder to reach a roof vent terminal. Using the 4-to-1 rule, how far should the base be from the wall if the ladder contacts the wall 16 ft up?
- Backflow prevention is a public-health safety requirement. What health event does a properly working backflow assembly prevent?
- A plumber replaces piping in a building constructed before 1978 and disturbs old painted surfaces and solder. What two legacy hazards require specific precautions?
- A 2,000 lb cast-iron section is lifted by a two-leg sling with each leg at 60 degrees from horizontal. Each leg carries (load / 2) / sin(60 degrees), with sin(60) about 0.866. What is the tension in each sling leg?
- During sewer confined-space work, the attendant outside must maintain what capability?