Brakes (A5)第 59 / 120 题
The metering valve in a combination valve is used to:
a.Increase rear brake pressure
b.Warn of ABS faults
c.Bleed the master cylinder
d.Delay front disc application so rear drums engage together
解析
The metering valve holds off front disc pressure briefly so the rear drum shoes overcome their return springs and apply at nearly the same time, balancing braking. The proportioning section limits rear pressure to prevent lockup. Together these balance front-to-rear braking.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- Technician A says a grinding, metal-on-metal noise during braking indicates friction material worn past its limit. Technician B says continued driving in that condition can score the rotor or drum. Who is correct?
- A rear disc parking brake that will not hold is often caused by:
- A brake caliper that sticks and does not release will most likely cause:
- When bleeding a conventional hydraulic brake system, the general rule is to bleed:
- A proportioning valve in the brake system is designed to:
- Technician A says silicone (DOT 5) and glycol (DOT 3/4) brake fluids can be freely mixed. Technician B says brake fluid type is unimportant. Who is correct?