Electrical (A6)第 71 / 120 题
A parasitic (key-off) battery drain is measured by connecting an ammeter:
a.In parallel across the battery terminals
b.Across a spark plug
c.In series between a battery terminal and the cable
d.Between two ground points
解析
Parasitic draw is measured by placing an ammeter in series in the battery circuit after modules go to sleep. Excessive draw discharges the battery overnight. Pulling fuses one at a time while watching the meter isolates the offending circuit.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- An open in a series circuit will cause:
- A starter that cranks slowly, with the battery known good and fully charged, most likely has:
- Power (watts) in an electrical circuit is calculated by:
- In a wiring diagram, a component shown connected to ground provides:
- Technician A says a fuse that blows again immediately after replacement indicates a short to ground or an overload. Technician B says repeatedly replacing the fuse will fix the circuit. Who is correct?
- Technician A says a diode allows current to flow in only one direction. Technician B says alternators use diodes to rectify AC into DC. Who is correct?