Water Supply & Distribution第 40 / 120 题
PEX tubing runs horizontally for 16 ft above a suspended ceiling. Using the maximum horizontal support spacing of 32 in for PEX, what is the minimum number of supports?
a.3 supports
b.4 supports
c.5 supports
d.6 supports
解析
Convert first: 16 ft equals 192 in, and 192 divided by 32 equals 6 supports. The 4 and 3 answers come from using 48 in or 72 in spacing, which apply to rigid materials, not flexible PEX. Five supports would leave one span longer than 32 in and would allow the tubing to sag.
法律依据: IPC Table 308.5免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A gauge on the building side of the meter shows a static street pressure of 96 psi with no flow. What does the plumbing code require?
- A 40 ft horizontal run of 3/4 in copper water tube is installed in a ceiling. Using a maximum horizontal support spacing of 6 ft for copper 1-1/2 in and smaller, what is the minimum number of hangers required?
- A 24 ft horizontal run of 1/2 in CPVC water distribution pipe is supported at the maximum spacing of 3 ft. What is the minimum number of supports required?
- To limit erosion-corrosion and noise, what is the generally accepted maximum design velocity in a copper hot water distribution line?
- A commercial kitchen is being piped with solenoid-operated quick-closing valves on the dishwasher and ice machine supplies. What does the code require on those branches?
- A potable water line supplies makeup water to a chemically treated boiler system and the connection is under continuous pressure. Which backflow prevention device is required?