Fixtures & Water Heaters第 80 / 120 题
A closet flange is set on a wood subfloor before the finished tile is installed, and the installer plans to seal the closet to the flange. Which practice is correct?
a.Set the flange below the finished floor and shim the bowl with wood blocks
b.Set the flange on top of the finished floor, secure it to the structure with fasteners, and seal with a wax or approved gasket
c.Seal the flange to the bowl with structural adhesive instead of fasteners
d.Rely on the closet bolts alone to hold the flange to the floor
解析
The closet flange must rest on and be mechanically secured to the finished floor or structure, and the joint between the bowl horn and the flange is sealed with a wax ring or an approved elastomeric gasket. A flange set below the finished floor leaves a gap that the seal cannot reliably bridge, and shimming with wood blocks is not an approved support method. Adhesive does not replace fasteners, and closet bolts secure the fixture to the flange rather than the flange to the floor.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A laundry standpipe for a residential clothes washer is roughed in with the top of the standpipe 14 inches above the trap weir. Is the installation acceptable?
- A showerhead is rated at the maximum allowable flow. A user showers for 8 minutes. Assuming the head flows at its rated maximum, how much water is used?
- A public restroom is fitted with metering faucets. What is the maximum volume of water each faucet may deliver per metering cycle?
- A restaurant installs a grease interceptor sized for 30 minutes of retention. If the connected fixtures produce a peak flow of 25 gallons per minute through the flow control device, what liquid capacity does the retention rule call for?
- A grease interceptor is inspected and found to contain accumulated grease and settled solids filling 25 percent of the total liquid depth. What action does the common maintenance standard require?
- A residence has a pressure reducing valve with a check on the incoming water service, and the 40 gallon water heater's relief valve has begun weeping each evening. What is the most likely cause and the correct correction?