Gas Piping第 87 / 120 题
A natural gas system runs from the meter through section A (12 ft), then section B (18 ft), then section C (35 ft) to the farthest appliance. Using the longest developed length method, which length is used to select the size of section A?
a.12 ft, the actual length of section A
b.30 ft, the length from the meter through section B
c.23 ft, the average of the three sections
d.65 ft, the total length from the meter to the farthest outlet
解析
The longest length method sizes every section of the system from the single length column that corresponds to the distance from the point of supply to the most remote outlet, here 12 + 18 + 35 = 65 ft. Using 12 ft or 30 ft applies a section length rather than the developed length to the farthest outlet and undersizes the pipe; averaging section lengths is not a recognized method.
法律依据: IFGC §402.4免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A house is served with natural gas having a heating value of about 1,000 Btu per cubic foot. The connected appliances are a 100,000 Btu/h furnace, a 40,000 Btu/h water heater and a 35,000 Btu/h clothes dryer. What total flow, in cubic feet per hour, must the piping downstream of the meter carry?
- The same 175,000 Btu/h total connected load is served by LP-gas instead of natural gas. Using about 2,500 Btu per cubic foot for propane, what flow must the piping carry?
- Measured along the pipe, the most remote gas outlet in a building is 78 ft from the meter. Sizing tables are printed in 10 ft length increments. Which length row should be used?
- A residential natural gas system is supplied at about 7 in w.c. from the utility meter. Which allowable pressure drop is normally used with the standard low-pressure sizing tables for this system?
- A gas furnace sits in a basement mechanical room. Its manual shutoff valve is installed in an adjacent storage room 9 ft away, behind a closed door. Why does this installation fail inspection?
- On which of the following appliances does the IFGC NOT require a sediment trap ahead of the appliance control valve?