Gas Piping第 87 / 120 题

A natural gas system runs from the meter through section A (12 ft), then section B (18 ft), then section C (35 ft) to the farthest appliance. Using the longest developed length method, which length is used to select the size of section A?

a.12 ft, the actual length of section A
b.30 ft, the length from the meter through section B
c.23 ft, the average of the three sections
d.65 ft, the total length from the meter to the farthest outlet

解析

The longest length method sizes every section of the system from the single length column that corresponds to the distance from the point of supply to the most remote outlet, here 12 + 18 + 35 = 65 ft. Using 12 ft or 30 ft applies a section length rather than the developed length to the farthest outlet and undersizes the pipe; averaging section lengths is not a recognized method.

法律依据: IFGC §402.4

免费刷完整 120 道题库 — 无需注册。

同考点相关题目

最近核对: · 审核流程

PrepPass 编辑团队 · 依据官方资料核对 Journeyman Plumber Licensing Exam (UPC/IPC-based) · 我们如何核对