Drainage, Waste & Vent第 9 / 120 题
A 3 in horizontal drain is run 72 ft at 1/8 in per ft. The invert at the upstream end is at elevation 100.00 ft. What is the invert elevation at the downstream end?
a.99.85 ft
b.99.90 ft
c.99.25 ft
d.98.50 ft
解析
The fall is 72 ft x 1/8 in = 9 in, and 9 in equals 0.75 ft, so the downstream invert is 100.00 - 0.75 = 99.25 ft. The 99.85 ft and 99.90 ft answers understate the drop by treating the fall as inches of elevation rather than converting to feet, and 98.50 ft doubles the correct fall.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A horizontal building drain changes direction with a fitting that turns the flow 90 degrees. What does the code require at that point?
- A 2 in trap arm serves a floor-mounted fixture. The trap weir is at elevation 0. What is the greatest amount the trap arm may fall before it reaches the vent connection?
- Which trap arrangement is expressly prohibited because it will siphon its own seal?
- A vent terminal passes through a roof that is used only for weather protection in an area with no snow-depth requirement. What is the minimum height the vent must extend above the roof surface?
- A vent terminal must be located away from an openable window. Which arrangement satisfies the code?
- Which fitting is acceptable for changing direction from horizontal to vertical in a drainage line?