Drainage, Waste & Vent第 21 / 120 题
An air admittance valve is used to vent an island sink. Which statement describes a correct installation?
a.It may be buried in insulation inside a sealed wall cavity
b.It relieves positive pressure in the drainage system
c.It must be accessible and located above the fixture trap weir
d.It replaces the need for any vent open to the atmosphere in the building
解析
An air admittance valve must remain accessible for service and be installed above the trap weir of the fixture it serves, in a space with air available to the valve. It admits air only and does not relieve positive pressure, it cannot be sealed off inside insulation, and the building still requires at least one vent open to the atmosphere.
法律依据: IPC §917免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A single 3 in vent stack is 46 ft in developed length and serves a drainage stack. If the code limits a given vent size to a maximum developed length, exceeding that length requires which action?
- Two lavatories are installed back to back on opposite sides of a wall and discharge into the same double fitting at the same level. What vent arrangement is being used?
- A kitchen sink is located in an island counter where no wall is available for a conventional vent. Which venting method is designed for this condition?
- What is the maximum vertical distance permitted between a fixture outlet and the trap weir serving that fixture?
- A commercial kitchen has a two-compartment sink whose drain must not connect directly to the sanitary drainage system. How must it discharge?
- A basement floor is below the elevation of the next upstream manhole on the public sewer. What device is required to protect the fixtures on that floor?