Drainage, Waste & Vent第 19 / 120 题
Two lavatories are installed back to back on opposite sides of a wall and discharge into the same double fitting at the same level. What vent arrangement is being used?
a.A common vent
b.A circuit vent
c.A relief vent
d.A wet vent
解析
A single vent serving two fixture drains that connect at the same level into the same fitting is a common vent. A circuit vent serves a battery of fixtures on a horizontal branch, a relief vent provides additional air circulation between drain and vent systems, and a wet vent is a drain that also carries vent air for other fixtures.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A 6 in horizontal drainage line requires a cleanout. What is the minimum size of the cleanout opening?
- Under the UPC, where does the building drain end and the building sewer begin?
- A single 3 in vent stack is 46 ft in developed length and serves a drainage stack. If the code limits a given vent size to a maximum developed length, exceeding that length requires which action?
- A kitchen sink is located in an island counter where no wall is available for a conventional vent. Which venting method is designed for this condition?
- An air admittance valve is used to vent an island sink. Which statement describes a correct installation?
- What is the maximum vertical distance permitted between a fixture outlet and the trap weir serving that fixture?