Fixtures & Water Heaters第 68 / 120 题
A 50 gallon water heater is installed in the attic above a finished ceiling. A drain pan is required. What is the minimum size of the pan drain line?
a.1/2 inch
b.5/8 inch
c.3/4 inch
d.1 inch
解析
Where leakage would cause damage to the structure, a pan is required and its indirect drain must be at least 3/4 inch in diameter, discharging to an approved location. 1/2 inch and 5/8 inch are undersized and would not carry the flow of a leaking tank. A 1 inch pan drain is permitted as an upsize but is not the code minimum being asked for.
法律依据: IPC §504.7免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A building owner replaces 40 old 3.5 gpf water closets with 1.28 gpf high efficiency models. If the fixtures are flushed a combined total of 2,000 times per day, how much water is saved per day?
- A storage type water heater is being installed. Which device must be provided on the tank to protect against both excessive temperature and excessive pressure?
- A temperature and pressure relief valve has a 3/4 inch outlet. Which discharge piping arrangement is acceptable?
- A gas fired water heater is installed in a residential garage in a seismic zone. It must be strapped in two places. Where must the lower strap be located relative to the heater's controls?
- The same gas water heater is installed in that garage on a concrete slab. What is the minimum height that the source of ignition must be elevated above the garage floor?
- A 120,000 Btu/h gas water heater draws all of its combustion air directly from outdoors through two vertical ducts. Using the 1 square inch per 4,000 Btu/h rule for vertical ducts, what is the required free area of each opening?