A gas fired water heater is installed in a residential garage in a seismic zone. It must be strapped in two places. Where must the lower strap be located relative to the heater's controls?
a.Directly across the control housing
b.At least 4 inches below the controls
c.At the exact vertical midpoint of the tank
d.At least 4 inches above the controls
解析
The two straps go around the upper third and the lower third of the tank, and the lower strap must be at least 4 inches above the controls so the strap does not damage or obstruct the gas valve and thermostat. Strapping across or below the controls interferes with service and with the control housing itself. A single midpoint strap does not satisfy the two-point bracing requirement.
免费刷完整 120 道题库 — 无需注册。
同考点相关题目
- A storage type water heater is being installed. Which device must be provided on the tank to protect against both excessive temperature and excessive pressure?
- A temperature and pressure relief valve has a 3/4 inch outlet. Which discharge piping arrangement is acceptable?
- A 50 gallon water heater is installed in the attic above a finished ceiling. A drain pan is required. What is the minimum size of the pan drain line?
- The same gas water heater is installed in that garage on a concrete slab. What is the minimum height that the source of ignition must be elevated above the garage floor?
- A 120,000 Btu/h gas water heater draws all of its combustion air directly from outdoors through two vertical ducts. Using the 1 square inch per 4,000 Btu/h rule for vertical ducts, what is the required free area of each opening?
- A 100,000 Btu/h water heater is placed in a closet and will take combustion air from inside the building only. Using the rule of thumb of 50 cubic feet of room volume per 1,000 Btu/h, what minimum volume of communicating space is needed?