Systems & Code第 38 / 110 题
A temperature-and-pressure (T and P) relief valve on a water heater is rated to open at 210 F and 150 psi. What is the required disposition of its discharge pipe?
a.Trapped and vented to the drain
b.Run full-size to within 6-24 in of the floor with no trap or valve
c.Reduced one size and terminated outside above grade
d.Connected to the recirculation return
解析
The T and P discharge must be full pipe size, contain no valves or traps, and terminate 6 to 24 in above the floor or an approved receptor so a discharge is visible and cannot be blocked. A trap would hold water and corrode; a valve could be shut and defeat the safety device. This prevents a tank from becoming a pressure vessel.
法律依据: UPC §608.3免费刷完整 110 道题库 — 无需注册。
同考点相关题目
- A building drain serving fixtures below the elevation of the public sewer manhole must be protected against sewer backflow. Which device is required on that low-level drainage?
- A basement floor drain sits 3 ft below the elevation of the upstream sewer manhole cover. During a main surcharge, how much backpressure head could push up through that drain if unprotected, using 0.433 psi per foot?
- A hot-water recirculation loop loses 4,000 BTU/hr to the piping. The pump must circulate enough water so it cools only 20 F while replacing that loss. Using Q (gpm) = BTU/hr / (500 x delta-T), what recirculation flow is required?
- A closed water-supply system (with a backflow preventer or check valve at the meter) has a water heater but no expansion control. As the water heats and expands, what device is required to prevent pressure buildup?
- A reduced-pressure principle (RP) backflow assembly is installed on a service subject to a health hazard. How must it be installed with respect to the ground and drainage?
- A lawn irrigation system with chemical injection is connected to a potable supply. This is classified as a high health hazard under backpressure and backsiphonage conditions. Which backflow assembly is required?