Finish TradesQuestion 284 of 700
In a suspended acoustical ceiling grid, the perimeter of the grid is supported by wall angle (edge molding). Where main runners and cross tees are cut at the walls, they should:
a.Rest on the wall angle so the perimeter is supported and the grid stays level
b.Float free of the wall with no support
c.Be glued to the drywall face
d.Hang only from the light fixtures
Explanation
The wall angle carries the cut ends of the grid at the room perimeter so the ceiling is supported all around and stays level and stable. Floating ends, gluing to drywall, or hanging from fixtures would leave the perimeter unsupported and sagging.
Practice all 700 questions free — no signup required.
Related questions on this topic
- Under CALGreen, composite wood used in interior casework, such as particleboard cabinet boxes, must meet formaldehyde emission limits. This requirement is set MAINLY to:
- In a bathroom that will receive paint (not tile), which gypsum board is a better choice for the walls and ceiling than standard board?
- On the interior of an attached garage, gypsum board fasteners into the ceiling of a garage with habitable space above are spaced to help the assembly perform. The garage-side board must generally be at least 5/8-inch Type X when there is living space above, MAINLY to:
- Glazing in the wall of a bathtub or shower enclosure is a hazardous location. Safety glazing is required where the bottom exposed edge of the glazing is less than ____ above the standing surface.
- A prehung interior door binds and does not latch after installation. The MOST likely finish-carpentry cause is that the door frame was:
- At an accessible interior door, the maximum force to push or pull the door open (not counting fire doors) is generally:
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review