Framing & StructuralQuestion 299 of 700

On a roof deck of wood structural panels installed without tongue-and-groove edges or solid blocking, what device is commonly used along unsupported panel edges to keep adjacent panels flush?

a.Hurricane ties
b.Framing clips
c.Draft stops
d.Panel edge (H) clips

Explanation

Panel edge clips (H-clips) are set between rafters at unsupported panel edges to align adjacent panels and share load, allowing a thinner panel for a given span. Hurricane ties resist uplift at bearings, framing clips connect members, and draft stops subdivide concealed spaces; none align roof panel edges.

Law Reference: 2025 CA Residential Code §R803.2.3

Practice all 700 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review