Framing & StructuralQuestion 373 of 700
On a stair with solid risers and treads less than 11 inches deep, a nosing is required. What projection range does the code specify for that nosing?
a.0 to 1/4 inch
b.1 to 2 inches
c.2 to 3 inches
d.3/4 inch to 1-1/4 inch
Explanation
Where a nosing is required, it must project between 3/4 inch and 1-1/4 inch beyond the riser below, giving extra effective foot depth without becoming a trip hazard. The other ranges are either too small to help or so large they create a catch point and are not code-compliant.
Law Reference: 2025 CA Residential Code §R311.7.5.3Practice all 700 questions free — no signup required.
Related questions on this topic
- At the top and bottom of a residential stairway, a floor or landing is required. What is the MINIMUM dimension of that landing measured in the direction of travel?
- For a circular (Type I) handrail, what is the required graspable cross-section?
- A required stair handrail must be continuous along the flight. How should the ends of the handrail be treated?
- CALCULATION: Two stair carriages (stringers) are each cut from a 2x12 that is 14 feet long. Using nominal dimensions, how many total board feet of lumber is that?
- A spiral stairway is permitted in a dwelling under special rules. Which requirement is characteristic of a code-compliant spiral stair?
- For a conventionally framed one-story dwelling using 2x4 studs, what is the MAXIMUM on-center spacing generally permitted for load-bearing wall studs supporting a roof and ceiling only?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review