Framing & StructuralQuestion 436 of 700

Under conventional framing rules, deep solid-sawn floor joists (such as nominal 2x10 or 2x12) generally require blocking or bridging installed at intervals not exceeding what maximum spacing?

a.4 feet on center along the joist span
b.8 feet on center along the joist span
c.12 feet on center along the joist span
d.No blocking is ever required for solid-sawn joists

Explanation

Deep joists whose depth-to-thickness ratio exceeds about six can twist or buckle, so blocking or cross bridging is required at intervals no greater than 8 feet along the span. 4 feet is stricter than the code minimum; 12 feet exceeds the limit and would leave the joists poorly restrained; claiming blocking is never required ignores lateral-stability rules for tall members.

Law Reference: 2025 CA Residential Code §R502.7

Practice all 700 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review
Report