In a dwelling, 125-volt 15- and 20-ampere receptacles must be GFCI-protected in which of the following groups of locations?

a.Bedrooms only
b.The living room
c.The attic
d.Bathrooms, kitchens, garages, outdoors, crawl spaces, unfinished basements, laundry areas, and within 6 feet of a sink

Explanation

The Code requires GFCI protection for dwelling receptacles in wet or damp and higher-risk areas—bathrooms, kitchens, garages, outdoors, crawl spaces, unfinished basements, laundry areas, and near sinks. Bedrooms, the living room, or the attic are not the code-listed GFCI locations by themselves.

Law Reference: 2023 NEC §210.8