Drainage, Waste & VentQuestion 140 of 360

The air gap for an indirect waste pipe discharging into a receptor must be at least…

a.1/2 inch
b.equal to the pipe diameter
c.3 inches minimum
d.twice the effective opening (diameter) of the indirect waste pipe, and not less than 1 inch

Explanation

An indirect waste air gap must be at least twice the effective opening of the drain pipe, measured vertically, and never less than 1 inch. This physical separation prevents sewage from backing up into the equipment through the indirect drain. It is the same principle used for potable-water air gaps.

Law Reference: 2022 California Plumbing Code (CPC) §801.2