Fixtures & Water HeatersQuestion 188 of 360
An atmospherically vented gas water heater relies on which principle to move flue gases out of the building?
a.A powered blower on the tank
b.Positive pressure from the gas supply
c.The natural buoyancy of hot flue gases rising through the vent (draft)
d.The T&P relief valve
Explanation
A natural-draft (atmospheric) water heater vents by the buoyancy of hot combustion gases rising through a properly sized and sloped vent connector and flue. Adequate draft depends on vent height, slope, and combustion air. Blockage or poor connector slope can cause dangerous spillage of flue gases.
Practice all 360 questions free — no signup required.
Related questions on this topic
- Thermal expansion in a domestic hot water system is primarily caused by:
- A gas water heater is installed in a residential garage. To reduce the risk of igniting flammable vapors, the ignition source should generally be elevated above the floor by at least:
- A fuel-gas water heater installed in a small closet requires combustion air primarily to:
- Under current California requirements, a new residential water closet may use a maximum flush volume of:
- The maximum flush volume allowed for a new urinal (other than wall-mounted) in California is generally:
- The federal WaterSense label on a plumbing fixture indicates that the fixture: