Water Supply & DistributionQuestion 21 of 360
You are supporting horizontal CPVC hot water pipe, 1 inch and smaller. What is the maximum horizontal support spacing typically required?
a.3 feet
b.6 feet
c.10 feet
d.12 feet
Explanation
For CPVC 1 inch and smaller, the support table typically requires a maximum horizontal spacing of about 3 feet because the plastic softens and sags at elevated temperatures. 6 feet applies to small copper, 10 feet to large copper, and 12 feet to steel.
Law Reference: 2022 California Plumbing Code (CPC) Table 313.3Practice all 360 questions free — no signup required.
Related questions on this topic
- A flushometer (flush valve) water closet is being served. Compared with a flush-tank water closet, what does the flushometer require from the water distribution design?
- A water service run has a developed length of 120 feet with an available pressure of 60 psi and a required residual of 15 psi at the highest fixture, which is 25 feet above the meter. Roughly how much pressure remains for friction loss in the piping (ignoring meter and fitting losses)?
- A janitor's service sink has a hose thread faucet used with cleaning chemicals. What is the simplest code-recognized protection against back-siphonage at that outlet?
- A reduced pressure principle assembly (RP) discharges water from its relief port during a fouling event. Where must the relief port discharge terminate?
- A hot water recirculation loop is added so users get hot water quickly at a remote fixture. What is the main plumbing purpose of the recirculation return line?
- Which standard applies to cross-linked polyethylene (PEX) tubing used in potable water distribution?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB C-36 Plumbing Trade Examination · How we review