Gas PipingQuestion 228 of 360
What is the primary purpose of a sediment trap (drip leg) installed ahead of a gas appliance control?
a.To increase gas pressure at the burner
b.To act as a required shutoff valve
c.To catch moisture and debris before they reach the appliance gas valve
d.To vent excess gas to the outdoors
Explanation
A sediment trap is a short capped nipple that catches condensate, scale, and dirt carried in the gas stream so they drop out instead of fouling the appliance gas control. It is installed downstream of the appliance shutoff valve and as close as practical to the appliance inlet. It does not regulate pressure or replace the shutoff valve.
Law Reference: California Plumbing Code, Fuel Gas provisionsPractice all 360 questions free — no signup required.
Related questions on this topic
- A natural gas furnace is rated at 100,000 BTU/hr input. Using a heating value of 1,000 BTU per cubic foot, what gas demand in cubic feet per hour (cfh) must the piping supply?
- Where must an accessible manual shutoff valve be located relative to a gas appliance it serves?
- A helper wants to route a flexible appliance connector through the back wall of a cabinet to reach the gas cooktop. What is the correct rule?
- For a rough-in pressure test of a new low-pressure gas piping system, which test condition is commonly required by the plumbing code?
- A propane (LP) appliance has an input of 75,000 BTU/hr. Using an approximate heating value of 2,500 BTU per cubic foot for propane, what is its demand in cfh?
- Corrugated stainless steel tubing (CSST) gas systems have an important electrical requirement. What is it?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB C-36 Plumbing Trade Examination · How we review