Gas PipingQuestion 238 of 360
A sediment trap is generally NOT required at which of the following appliances?
a.A listed range, clothes dryer, or outdoor grill, where exempted by code
b.A gas furnace
c.A gas water heater
d.A gas boiler
Explanation
Code generally exempts certain appliances such as listed ranges, clothes dryers, and outdoor grills from the sediment-trap requirement, while furnaces, boilers, and water heaters still require one. The trap protects the automatic gas valve on heating appliances from moisture and debris. Always check the specific list in the adopted code and the appliance instructions.
Law Reference: California Plumbing Code, Fuel Gas provisionsPractice all 360 questions free — no signup required.