Gas PipingQuestion 252 of 360
A gas furnace uses a draft hood and relies on natural draft to move flue gases up the vent. This describes which general appliance venting category?
a.A direct-vent sealed-combustion appliance
b.A power-vented appliance requiring PVC
c.A Category I appliance with a draft hood venting by natural draft
d.An unvented decorative appliance
Explanation
An appliance with a draft hood that vents by natural draft and produces non-condensing, low-pressure flue gases is generally a Category I appliance, typically vented with Type B vent or a lined masonry chimney. Direct-vent and power-vent appliances use sealed or mechanically assisted venting and different materials. Matching the vent to the appliance category is essential for safe combustion product removal.
Practice all 360 questions free — no signup required.
Related questions on this topic
- What best describes CSST used in gas distribution?
- Two runs leave the meter: Run A is 55 feet to the farthest outlet; Run B is 30 feet. Using the longest-length method, which length column governs sizing of the entire system?
- An appliance shutoff valve is being installed. Which condition satisfies the accessibility requirement?
- Why must clearances to combustibles for a single-wall metal vent connector and for Type B vent be respected during installation?
- A branch serves two appliances downstream: a 30,000 BTU/hr wall heater and a 120,000 BTU/hr furnace. In natural gas cfh, what demand governs that branch?
- A sediment trap is typically built from a tee and a nipple. What is a reasonable minimum length for the capped drip nipple so it can actually collect debris?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB C-36 Plumbing Trade Examination · How we review