Drainage, Waste & VentQuestion 86 of 360
Horizontal vent piping must be graded so that it:
a.Runs perfectly level
b.Drains any condensate back to the drainage pipe by gravity
c.Slopes away from the drainage system
d.Is installed only vertically
Explanation
Horizontal vent pipes must maintain a slope back toward the drainage piping so condensate and any moisture drain back by gravity and do not pool inside the vent. A level or reverse-sloped vent allows water to collect and block airflow. Vents are not restricted to vertical runs.
Law Reference: 2022 California Plumbing Code (CPC) §905.0Practice all 360 questions free — no signup required.
Related questions on this topic
- A single wet vent may serve fixtures within a maximum of how many bathroom groups?
- A circuit vent may serve a battery of not more than how many fixtures?
- A combination waste and vent system is typically used for:
- A vent must rise vertically to a point above the flood-level rim of the highest fixture served before it may offset horizontally, by at least:
- What is the minimum diameter permitted for any vent pipe?
- A horizontal branch serves two lavatories (1 DFU each), one kitchen sink (2 DFU), and one bathtub (2 DFU). What is the total DFU and minimum branch size?