Drainage, Waste & VentQuestion 91 of 360
A 3 inch drain runs 48 feet at the minimum slope of 1/8 inch per foot. What is the total fall?
a.12 inches
b.3 inches
c.6 inches
d.9 inches
Explanation
Total fall equals 48 feet times 1/8 inch per foot = 6 inches. Twelve inches would be the fall at 1/4 inch per foot, which is steeper than the minimum. Three and nine inches do not match a 48 foot run at 1/8 inch per foot.
Law Reference: 2022 California Plumbing Code (CPC) §708.1Practice all 360 questions free — no signup required.
Related questions on this topic
- What is the minimum diameter permitted for any vent pipe?
- A horizontal branch serves two lavatories (1 DFU each), one kitchen sink (2 DFU), and one bathtub (2 DFU). What is the total DFU and minimum branch size?
- A horizontal drain run is 80 feet long at 1/4 inch per foot slope. What is the total fall over the run?
- Over its length, the total fall of a trap arm must not exceed:
- For a 1-1/4 inch trap arm, the maximum developed length to the vent is:
- For a 4 inch trap arm, the maximum developed length to the vent is:
Last reviewed: · editorial process