Systems & CodeQuestion 36 of 110

A basement floor drain sits 3 ft below the elevation of the upstream sewer manhole cover. During a main surcharge, how much backpressure head could push up through that drain if unprotected, using 0.433 psi per foot?

a.0.43 psi
b.3.0 psi
c.13 psi
d.1.3 psi

Explanation

Backpressure = depth below the surcharge level x 0.433 = 3 x 0.433 = 1.3 psi. Even a modest 3 ft head can flood a basement, which is why fixtures below the manhole rim require a backwater valve. The valve seats against reverse flow while still passing normal drainage.

Law Reference: UPC §710.0