Supply and return ducts installed in an unconditioned attic are typically required to be insulated and sealed MAINLY to:
a.Reduce noise only
b.Support the ductwork
c.Match the color of the attic
d.Limit conductive heat loss/gain and air leakage so the system meets efficiency requirements
Explanation
Ducts in unconditioned space lose or gain heat and leak air, wasting energy; insulating and sealing them limits conductive losses and leakage so the system performs efficiently as required by the Energy Code. Noise, support, and color are not the primary reasons.
Law Reference: 2025 CA Energy Code (Title 24, Part 6)Practice all 700 questions free — no signup required.
Related questions on this topic
- CALCULATION: A room measures 20 ft by 15 ft with a 10-ft ceiling. A ventilation system supplies 500 cubic feet per minute (CFM). Approximately how many air changes per hour (ACH) does this provide?
- A clothes dryer exhaust duct is run with several sharp bends and a long concealed length, then vented into an attic. Two problems with this install are:
- A high-efficiency (condensing) furnace produces acidic condensate. This condensate must be:
- At the intersection of two sloping roof planes, water collects and flows in a channel. The flashing installed in this channel is called:
- Where a sloped shingle roof meets a vertical sidewall, the correct flashing method is:
- On a low-slope shingle roof, underlayment courses must be lapped so water sheds over each lower course. The MAIN reason for the larger head and side laps on low slopes is:
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review