A kickout (diverter) flashing is installed where a roof edge meets a vertical wall at the bottom of a roof-wall intersection. Omitting it commonly causes:
a.Water dumping behind the wall cladding, leading to hidden rot at that corner
b.The roof to lift in wind
c.Excessive attic ventilation
d.The gutter to overflow upward
Explanation
A kickout flashing diverts roof runoff away from the wall and into the gutter; without it, concentrated water runs behind the siding at that corner and causes hidden rot and interior damage. It is unrelated to wind uplift, attic ventilation, or upward overflow.
Law Reference: 2025 CA Building Code / CRC (Weather Protection)Practice all 700 questions free — no signup required.
Related questions on this topic
- Fiberglass batt insulation is compressed and stuffed tightly around wiring and into a cavity that is too shallow. The effect on thermal performance is:
- In a mixed California climate, a vapor retarder placed on the WRONG side of the insulation can cause:
- CALCULATION: A ceiling requires R-49 insulation. If a certain blown insulation provides R-3.5 per inch, what minimum installed thickness is needed?
- Under normal ambient conditions, what is the MINIMUM period that standard structural concrete should be kept continuously moist to develop adequate strength and durability?
- What is the MINIMUM concrete cover required to protect reinforcing steel in concrete that is cast against and permanently exposed to earth?
- A rectangular slab measures 30 ft by 40 ft and is 4 inches thick. How many cubic yards of concrete are needed (before any waste allowance)?