Limiting the developed length of a fixture's trap arm (the distance from the trap to its vent) is important PRIMARILY to:

a.Prevent the trap from losing its water seal by self-siphonage
b.Increase the flow rate through the fixture
c.Reduce the amount of pipe material used
d.Allow the trap to be installed without a cleanout

Explanation

Keeping the trap arm within its maximum length prevents self-siphonage that would pull the water seal out of the trap and let sewer gas enter. It is not primarily about saving pipe, boosting flow, or avoiding cleanouts.

Law Reference: 2025 CA Plumbing Code, Chapter 9 (Vents)