Framing & StructuralQuestion 353 of 700
When metal lath for three-coat stucco is fastened to a wood-framed wall, how far should the fasteners penetrate the framing?
a.Just into the sheathing
b.No penetration is needed if the lath is tight
c.Only into the WRB
d.Into the studs or supports far enough to hold the lath securely (commonly at least about 3/4 to 1 inch)
Explanation
Lath fasteners must reach into the studs or solid supports enough (commonly on the order of 3/4 to 1 inch) so the lath and the heavy wet plaster cannot pull loose. Fastening only to sheathing, to the WRB, or relying on tight lath without penetration will not hold the plaster.
Law Reference: 2025 CA Residential Code §R703.7Practice all 700 questions free — no signup required.
Related questions on this topic
- Behind exterior cement plaster (stucco) applied over wood-based sheathing, how many layers of water-resistive barrier does the code generally require?
- A weep screed at the base of a stucco wall must be located at least how far above adjacent surfaces?
- CALCULATION: Cement plaster control joints are recommended to divide large wall areas into panels not exceeding 144 square feet. On a wall panel 8 feet tall, at about what horizontal spacing should control joints fall to stay within that limit?
- In traditional three-coat stucco over metal lath, the total nominal thickness is about 7/8 inch. Which sequence of coats builds that thickness?
- Fiber-cement lap siding is installed on a wood-framed wall. What clearance is generally required between the bottom edge of the siding and the finished grade or a roof surface below it?
- Why is vinyl siding fastened so that the panels can move slightly (nails not driven tight) rather than pinned firmly?