Fiber-cement lap siding is installed on a wood-framed wall. What clearance is generally required between the bottom edge of the siding and the finished grade or a roof surface below it?
a.No clearance; siding may touch the ground
b.A clearance (commonly around 6 inches to earth and about 1 to 2 inches above a roof) to keep the siding out of standing water and splash
c.At least 12 inches above a roof
d.Siding must be buried 2 inches into the grade
Explanation
Manufacturers and the code call for clearance at the bottom of fiber-cement (and most) siding, commonly about 6 inches to earth and roughly 1 to 2 inches above roof surfaces, to keep the siding out of standing water and splash that would wick moisture. No clearance, 12 inches above a roof, or burying the siding are incorrect.
Law Reference: 2025 CA Residential Code §R703.3Practice all 700 questions free — no signup required.
Related questions on this topic
- CALCULATION: Cement plaster control joints are recommended to divide large wall areas into panels not exceeding 144 square feet. On a wall panel 8 feet tall, at about what horizontal spacing should control joints fall to stay within that limit?
- When metal lath for three-coat stucco is fastened to a wood-framed wall, how far should the fasteners penetrate the framing?
- In traditional three-coat stucco over metal lath, the total nominal thickness is about 7/8 inch. Which sequence of coats builds that thickness?
- Why is vinyl siding fastened so that the panels can move slightly (nails not driven tight) rather than pinned firmly?
- Where three-coat stucco terminates at a window, door, or dissimilar material, what accessory provides a clean, sealed edge?
- When self-furring metal lath is used for stucco, what does the 'self-furring' feature accomplish?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review