Core TradesQuestion 84 of 700
When routing a nonmetallic-sheathed cable through holes bored in wood studs, the code generally requires that the hole be kept back from the stud edge, or a steel plate be installed, primarily to:
a.Keep the cable straight
b.Improve the wall's fire rating
c.Protect the cable from nails and screws driven into the framing
d.Reduce voltage drop
Explanation
Bored holes must be set back from the framing edge (commonly about 1-1/4 inch) or protected by a steel plate so drywall screws and nails cannot pierce the cable. It is a physical-protection rule, not about straightness, fire rating, or voltage drop.
Law Reference: 2025 CA Electrical Code (based on NEC)Practice all 700 questions free — no signup required.
Related questions on this topic
- A subpanel is fed from the main service panel in a detached structure. In a modern installation, the neutral (grounded) and equipment grounding (ground) conductors at the subpanel must be:
- A homeowner reports that a bedroom outlet works but the tester shows an open ground. The MOST likely cause is:
- CALCULATION: A branch circuit is protected by a 20-ampere breaker. Applying the common rule that a continuous load should not exceed 80 percent of the breaker rating, what is the maximum continuous load in amperes?
- A fixture drain is located far from any vent, and after installation the trap seals siphon out, letting sewer gas into the room. The MOST likely code violation is:
- An air admittance valve (AAV) is installed to vent an island sink where a conventional vent is impractical. The AAV must be installed:
- CALCULATION: A 3-inch horizontal drain pipe is installed at the common 1/4 inch per foot slope. Over a 40-foot run, how much does the invert drop from start to end?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review