Drainage, Waste & VentQuestion 128 of 360
A horizontal wet-vent system under the CPC is limited to serving fixtures within…
a.any group of fixtures on one floor
b.a kitchen and laundry group
c.up to eight fixtures of any type
d.one or two bathroom groups on the same floor level
Explanation
Wet venting under the CPC is limited to the fixtures of one or two bathroom groups located on the same floor level. The drain of an upstream fixture serves as the vent for a downstream fixture, so the arrangement is restricted to controlled bathroom-group layouts. Kitchen and laundry fixtures are not part of a wet-vented bathroom group.
Law Reference: 2022 California Plumbing Code (CPC) §908.0Practice all 360 questions free — no signup required.
Related questions on this topic
- Where are air admittance valves (AAVs) prohibited from being installed?
- What term describes a vent that connects to the drain of a single fixture and extends independently to the outside air or to another vent?
- Two fixtures connected at the same level to a vertical drain and served by a single shared vent are using which venting method?
- In a bathroom-group wet vent, where is the dry vent connection typically made?
- A circuit vent serving a battery of floor-mounted fixtures on a horizontal branch may serve a maximum of how many fixtures?
- A kitchen island sink with no adjacent wall for a conventional vent is best served by which venting arrangement?