Drainage, Waste & VentQuestion 130 of 360

A circuit vent serving a battery of floor-mounted fixtures on a horizontal branch may serve a maximum of how many fixtures?

a.6
b.8
c.10
d.12

Explanation

A circuit vent may serve a battery of up to 8 fixtures connected to a horizontal branch drain. A single vent rises between the last two fixtures to serve the whole battery, and a relief vent may be required where fixtures discharge above. This method suits banks of floor-mounted water closets or urinals.

Law Reference: 2022 California Plumbing Code (CPC) §911.0