Water Supply & DistributionQuestion 14 of 360
A double check valve assembly (DC) is being selected for a cross-connection. Which application is appropriate for a DC assembly?
a.A high (health) hazard with chemical contamination
b.A low-hazard (non-health) cross-connection, including backpressure situations
c.Any hazard as long as an air gap is impossible
d.A back-siphonage-only application where an AVB is cheaper
Explanation
A double check assembly protects against both back-siphonage and backpressure but only for low-hazard (non-health) cross-connections. It is not rated for a high (health) hazard, which requires an RP assembly or air gap, so the other options misapply the device.
Law Reference: 2022 California Plumbing Code (CPC) §603.0Practice all 360 questions free — no signup required.
Related questions on this topic
- A lawn sprinkler system has no chemical injection and no possibility of backpressure, only back-siphonage under continuous pressure. Which device is the appropriate minimum protection?
- A residence has a closed water supply system because the water meter contains a check valve and a pressure regulator. As the water heater heats water, pressure spikes dangerously. What does the code require to relieve this?
- Which of the following is an approved standard material for potable cold and hot water distribution piping inside a building?
- A branch serves fixtures totaling 8 WSFU. Design velocity should be kept at or below about 8 feet per second to limit erosion and noise. If a given pipe size carries the demand at 6 fps, and the next size down would run at 11 fps, which is the better selection and why?
- What is the fundamental purpose of cross-connection control in a potable water system?
- When sizing water piping using the fixture unit method, why is the total demand in gpm always less than the simple sum of every fixture's peak flow?