Drainage, Waste & VentQuestion 145 of 360

The size of a hydromechanical grease interceptor is primarily selected based on…

a.the flow rate (GPM) of the fixtures it serves and its rated grease retention capacity
b.the color of the discharge
c.the length of the drain line only
d.the number of restrooms in the building

Explanation

A hydromechanical (point-of-use) grease interceptor is selected by the flow rate in GPM it must handle and its rated grease capacity in pounds. A flow-control fitting limits flow to the rated GPM so grease can separate. Undersizing lets grease pass straight through to the sewer.

Law Reference: 2022 California Plumbing Code (CPC) §1014.0

Practice all 360 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against California CSLB C-36 Plumbing Trade Examination · How we review