Drainage, Waste & VentQuestion 146 of 360
The required size of vertical and horizontal storm (rainwater) piping is determined from code tables based on the projected roof area and…
a.the number of floor drains
b.the local rainfall rate in inches per hour
c.the building trap size
d.the sanitary DFU count
Explanation
Storm drain and leader sizing is based on the horizontally projected roof area served and the local design rainfall rate in inches per hour. A higher rainfall rate or larger roof area requires larger pipe. Local jurisdictions publish the design storm intensity used for these calculations.
Law Reference: 2022 California Plumbing Code (CPC) §1101.0Practice all 360 questions free — no signup required.
Related questions on this topic
- Which establishment is most likely required to install a grease interceptor or grease trap?
- A gravity grease interceptor (the large in-ground type) commonly has a minimum liquid capacity of…
- The size of a hydromechanical grease interceptor is primarily selected based on…
- A vent must rise vertically to at least what point before it may offset horizontally, to keep waste water out of the dry vent?
- For a 2-inch trap arm, the maximum developed length from the trap weir to the vent (per the CPC trap-to-vent table) is approximately…
- Besides not being directly beneath a door, openable window, or air intake, a side-wall (through-wall) vent termination must also maintain required clearance from…