SafetyQuestion 330 of 360

A plumber's gas meter reads the oxygen level inside a sewer vault. What is the acceptable oxygen range for safe entry under Cal/OSHA?

a.19.5% to 23.5%
b.10% to 30%
c.5% to 15%
d.Any level above 12%

Explanation

Under Title 8 §5157, the atmosphere is safe for oxygen only between 19.5% (oxygen-deficient below this) and 23.5% (oxygen-enriched above this). Below 19.5% a worker can lose consciousness; above 23.5% the enriched atmosphere greatly increases fire risk. Readings outside this range mean the space must be ventilated and retested before entry.

Law Reference: Cal/OSHA Title 8 §5157