Testing a sewer manhole, the meter shows the flammable gas reading as a percentage of the Lower Explosive Limit (LEL). Below what LEL reading does Cal/OSHA generally consider the flammable atmosphere acceptable for entry?

a.Below 50% of the LEL
b.Below 10% of the LEL
c.Below 90% of the LEL
d.Any reading is fine if oxygen is normal

Explanation

Under Title 8 §5157, a flammable atmosphere is acceptable for entry only when combustible gas or vapor is below 10% of the Lower Explosive Limit. The LEL is the lowest concentration that can ignite, so the 10% margin provides a large safety buffer against explosion. Sewers can accumulate methane from decomposing waste, so continuous monitoring is essential.

Law Reference: Cal/OSHA Title 8 §5157