Water Supply & DistributionQuestion 55 of 360

A two-story home has the main run in the crawlspace and risers to the second floor. To minimize pressure loss to upstairs fixtures during simultaneous use, which strategy is best?

a.Undersize the risers to save material
b.Add extra elbows to slow the water
c.Size the trunk and risers for the combined demand and keep developed length and fittings reasonable
d.Remove the shutoff valves

Explanation

Sizing the trunk and risers for the combined simultaneous demand while keeping developed length and fittings reasonable minimizes friction and pressure loss to upstairs fixtures. Undersizing risers, adding elbows, or removing valves would increase loss or reduce control, not help.

Law Reference: 2022 California Plumbing Code (CPC) §610.0