Drainage, Waste & VentQuestion 63 of 360
Each fixture trap must have a water seal with a depth of not less than and not more than:
a.1 to 2 inches
b.1-1/2 to 3 inches
c.2 to 4 inches
d.3 to 5 inches
Explanation
The CPC requires each trap to have a liquid seal of not less than 2 inches and not more than 4 inches, except for special deep-seal traps. A shallower seal is easily lost to evaporation or siphonage, and a deeper seal beyond code is only allowed for approved deep-seal designs. The other ranges fall outside the required 2 to 4 inch window.
Law Reference: 2022 California Plumbing Code (CPC) §1002.0Practice all 360 questions free — no signup required.
Related questions on this topic
- What is the minimum slope for a 2 inch horizontal drainage pipe?
- A 4 inch building drain must be installed at a minimum slope of:
- For a 1-1/2 inch trap arm, the maximum developed length from the trap weir to the vent is:
- Cleanouts in horizontal drainage lines must be spaced no more than:
- The minimum diameter of a vent pipe must be:
- What is the minimum clearance required in front of a cleanout on a 4 inch drainage pipe?