Branch Circuits & FeedersQuestion 18 of 120
In a dwelling unit, 125-volt receptacles installed within what distance of the outside edge of a sink require GFCI protection?
a.5 feet
b.3 feet
c.6 feet
d.10 feet
Explanation
The measurement is 6 feet from the outside edge of the sink, taken along the shortest path a cord would follow without piercing a wall or partition. The 3-foot dimension belongs to other rules such as service conductor clearance from openable windows, and 5 or 10 feet are not used for the sink measurement.
Law Reference: 2023 NEC §210.8(A)Practice all 120 questions free — no signup required.
Related questions on this topic
- A four-wire, three-phase, 208Y/120-volt feeder supplies electric-discharge lighting, and the major portion of the load is nonlinear. How many current-carrying conductors are counted for adjustment purposes?
- Where must a multiwire branch circuit have a means to simultaneously disconnect all ungrounded conductors?
- In a dwelling unit living room, no point measured horizontally along the floor line of any wall space may be more than what distance from a receptacle outlet?
- Arc-fault circuit-interrupter protection is required for 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets in which dwelling unit areas?
- A 277-volt feeder supplies three continuous lighting loads of 12, 15 and 18 amperes. What is the minimum standard feeder overcurrent device rating?
- For that same 45-ampere continuous lighting feeder, what is the minimum copper conductor size at 75 degrees C terminations?