Codes & SafetyQuestion 105 of 120
Model plumbing codes are published on a three-year cycle. A state adopts one of those editions with statewide amendments, and a city then adopts the state code with additional local amendments. Which document governs an installation in that city?
a.The most recent model code edition published, whether or not the jurisdiction has adopted it
b.The model code as published, because the local amendments only apply to commercial work
c.The edition adopted by the jurisdiction, as amended, since a model code has no legal force until it is adopted
d.The manufacturer's installation instructions, which always supersede any adopted code
Explanation
A model code is a template with no legal effect on its own; it becomes enforceable only when a state or local jurisdiction adopts it, usually with amendments that reflect local climate, soil and practice. The locally adopted amended edition therefore controls, and the authority having jurisdiction interprets it, with a board of appeals available to hear disputes over that interpretation. Newer published editions do not apply until adopted, which is why a jurisdiction may still be enforcing an edition several cycles old. Manufacturer instructions must be followed for listed and labeled products but cannot override an adopted code requirement.
Practice all 120 questions free — no signup required.
Related questions on this topic
- A homeowner hires a plumbing company to replace a water heater and reroute the gas line to it. A journeyman employed by that company will perform the installation. Under a typical adopted plumbing code, who is authorized to apply for and hold the permit?
- Underground drainage piping is installed, and the crew backfills and compacts the trench before the groundwork inspection is called for. What does the code require?
- A drainage, waste and vent system is being water tested. Which statement describes the test correctly?
- A high-rise DWV system is water tested in sections. The highest joint in the section currently under test is 28 ft above the building drain, and three more floors of piping continue above that section. To what height above the building drain must the test standpipe extend?
- Freezing weather makes a water test impractical, so the DWV rough-in is air tested instead. Which combination of test pressure and duration satisfies the code?
- A water distribution system that will operate at 45 psi working pressure is tested with water. The plumber pumps it to 48 psi, and after 15 minutes the gauge reads 46 psi. How should the result be reported?