Drainage, Waste & VentQuestion 30 of 120
A row of five lavatories on a common horizontal branch in a public restroom is vented by a single vent connected between the last two fixture drains. What type of venting is this?
a.Circuit vent
b.Common vent
c.Island vent
d.Individual vent
Explanation
A circuit vent serves a battery of fixtures on a horizontal branch with one vent taken off ahead of the last fixture connection. A common vent serves only two fixtures connecting at the same level, an island vent is a loop arrangement for a fixture with no wall, and an individual vent serves one fixture drain.
Practice all 120 questions free — no signup required.
Related questions on this topic
- A 4 in horizontal drain is sized to carry a load of drainage fixture units. Which pipe run carries the greatest DFU load for a given diameter?
- A branch serves one water closet at 4 DFU, one lavatory at 1 DFU, one bathtub with shower at 2 DFU, and one kitchen sink at 2 DFU. What is the total DFU load on that branch?
- A horizontal fixture branch serves three lavatories only. Any branch that receives the discharge of a water closet must be at least what size?
- A 1-1/4 in trap arm serves a small lavatory. The vent is located 3 ft of developed length from the trap weir. What is the correct evaluation?
- An 8 in building drain is proposed at 1/16 in per ft over a 200 ft run. What is the fall, and is that slope permitted?
- A bathroom group is arranged so that the lavatory drain also serves as the vent for the bathtub downstream of it. What is this arrangement called, and what limits it?