Water Supply & DistributionQuestion 54 of 120
A dwelling unit contains one flush tank water closet (2.5 WSFU), two lavatories (1.0 WSFU each), one bathtub with shower (4.0 WSFU), one kitchen sink (1.5 WSFU), one dishwasher (1.5 WSFU), and one clothes washer (4.0 WSFU). What is the total water supply fixture unit load?
a.15.5 WSFU
b.14.5 WSFU
c.16.5 WSFU
d.13.0 WSFU
Explanation
Adding the listed values gives 2.5 + 1.0 + 1.0 + 4.0 + 1.5 + 1.5 + 4.0 = 15.5 WSFU. The 14.5 answer counts only one lavatory, and 13.0 drops the dishwasher. The 16.5 answer adds an extra fixture unit that is not in the list; the total load is then carried into the sizing table to pick the service and distribution sizes.
Practice all 120 questions free — no signup required.
Related questions on this topic
- Static pressure at the main is 72 psi. Meter loss at design flow is 9 psi, the highest fixture is 26 ft above the meter, and 15 psi residual is required at that fixture. How much pressure is available to overcome friction loss in the piping?
- A flushometer water closet on the top floor requires 20 psi residual. Static pressure is 65 psi, combined meter and backflow preventer loss is 10 psi, and the flush valve is 34 ft above the meter. How much pressure remains for friction loss in the piping and fittings?
- A sizing problem leaves 24 psi available for friction loss. The measured developed length to the most remote fixture is 160 ft, and fittings are estimated to add 50 percent to that length. What is the allowable friction loss per 100 ft of pipe?
- Using the standard fixture unit to gpm conversion curve, what happens to the estimated demand when the total water supply fixture unit load on a system is doubled?
- What is the minimum nominal size normally permitted for a water service pipe serving a building?
- The highest fixture in a building is 28 ft above the meter and requires 15 psi residual. Meter loss is 5 psi and calculated friction loss in the piping is 12 psi. What minimum static pressure is needed at the meter?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against Journeyman Plumber Licensing Exam (UPC/IPC-based) · How we review