Advanced WiringQuestion 75 of 110

Electrical equipment supplying a decorative fountain must have what protection?

a.AFCI
b.Surge protection
c.GFCI
d.Isolation transformer only

Explanation

All electrical equipment associated with fountains, including luminaires and pumps, must be protected by a ground-fault circuit interrupter.

Law Reference: 2023 NEC 680.51(A)