A trench 10 ft deep in Type B soil is sloped at 1 to 1 (horizontal to vertical) on both sides. If the trench bottom is 3 ft wide, how wide is the excavation at the top?
a.13 ft
b.20 ft
c.23 ft
d.30 ft
Explanation
Each side slopes back 1 x depth = 10 ft, so the top width = bottom + 2 x 10 = 3 + 20 = 23 ft. Type B soil requires a 1-to-1 slope, while less stable Type C requires 1.5 to 1 and would open even wider. The soil classification set by a competent person drives the excavation width and spoil space needed.
Law Reference: 29 CFR 1926.652Practice all 110 questions free — no signup required.
Related questions on this topic
- A plumber replaces piping in a building constructed before 1978 and disturbs old painted surfaces and solder. What two legacy hazards require specific precautions?
- A 2,000 lb cast-iron section is lifted by a two-leg sling with each leg at 60 degrees from horizontal. Each leg carries (load / 2) / sin(60 degrees), with sin(60) about 0.866. What is the tension in each sling leg?
- During sewer confined-space work, the attendant outside must maintain what capability?
- A trench 90 ft long and 6 ft deep requires egress so no worker travels more than 25 ft laterally to a ladder. A ladder placed mid-run protects 25 ft in each direction, or 50 ft total. What is the minimum number of ladders required?
- Before servicing a sewage ejector pump, the plumber must control hazardous energy. What procedure prevents the pump from starting during service?
- On a California jobsite, a trench 5 ft or deeper in which workers will enter also requires a specific state permit beyond federal rules. What is that requirement?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against Master Plumber Licensing Exam (UPC/IPC-based) · How we review